上海桂戈小型喷雾干燥机常见问题排除

问题 Problem 可能原因 Possible Causes 解决方法 Solution
1.风机不工作
1. Fan can not work
1.中间继电器R201.2 损坏
2.变频器损坏
3. 风机损坏
1.Intermediate relay R201.2 damage
2. Inverter damage
3. Fan damage
1.更换R201.2
2.与GUIGO 联系
3.与GUIGO 联系
1. change R201.2
2. contact GUIGO
3. contact GUIGO
2、电加热器不工作
2.Electric Heater not work
1.风机未启动
2.固态继电器SSR201 损坏
3.电加热器损坏
1. Do not start the fan
2. Solid State Relay damage
3. Electric Heater damage
1.启动风机
2.更换固态继电器SSR201
3.与GUIGO 联系
1. start fan
2. change Solid State Relay
3. contact GUIGO
3、空气压缩机不工作
3. Air compressor not work
1.中间继电器R201.1 损坏
2.空压机未启动
3.空压机损坏
1.Intermediate relay R201.2 damage
2. Air compressor does not start
3. Air compressor damage
1.更换R201.1
2.启动空压机
3.与GUIGO 联系
1. change R201.2
2. Start air compressor
3. contact GUIGO
4、设备没电
4. Equipment has no power
1. 外加插座不可靠
2. 断路器NFB 在关闭位置
1. socket unreliable
2. Breaker NFB is off
1. 检查外接电源是否有电
2. 把NFB 打开
1. Check the socket
2. Turn on the NFB
5、HMI 触摸屏无显示工作
5. HMI Touch screen nodisplay
1. 面板启动按钮损坏
2. 开关电源损坏
3. 中间继电器R1.2 损坏
4. 触摸屏损坏
1. Start button on panel is damaged
2. Power supply switch is damaged
3. Intermediate relay R1.2 damage
4. Touch screen damage
1. 更换启动按钮
2. 更换开关电源
3. 更换R1.2
4. 与GUIGO 联系
1. Change start button on the panel
2. Change power supply switch
3. change R1.2
4. contact GUIGO
6、PLC 不工作
6. PLC can not work
1.断路器NFB 在关闭位置
2.中间继电器R1.1 损坏
3.PLC 损坏
1. Breaker NFB is off
2. Intermediate relay R1.1 damage
3. PLC damage
1.打开NFB
2.更换R1.1
3. 与GUIGO 联系
1. Turn on the NFB
2. Change R1.1
3. contact GUIGO
7、进风温度无显示
7. Temp of air inlet doesnot display
1. PT-100 温度探头连接松动
2. PT-100 损坏
3. PT 温度模块损坏
1. PT-100 Temp probe connection is
loose
2. PT-100 damage
3. PT temp block damage
1. 紧固
2. 与GUIGO 联系
3. 与GUIGO联系
1. Fix it
2. contact GUIGO
3. contact GUIGO
8、出风温度无显示
8. Temp of air outlet doesnot display
1. PT-100 温度探头连接松动
2. PT-100 损坏
3. PT 温度模块损坏
1. PT-100 Temp probe connection is
loose
2. PT-100 damage
3. PT temp block damage
1. 紧固
2. 与GUIGO联系
3. 与GUIGO联系
1. Fix it
2. contact GUIGO
3. contact GUIGO
9.进风温度无法达到设定值
9. Temp of air inlet can notmeet to the setting value
风机风量太大
Fan flow is too big
修改风机参数
Update flow parameters of fan
10、进风温度波动大
10. Temp of air inlet with big fluctuation
PID 值不准确
PID value is not accurate
进行进风温度自调
Make the air inlet temp adjusted automatically.
11.出风温度无法达到设定值
11. Temp of air outlet cannot meet to the setting value
进风量太大(蠕动泵手动时)
Air inlet flow is too big (Peristaltic pump)
修改蠕动泵参数
Update value of peristaltic pump
12.出风温度波动大
12. Temp of air outlet with big fluctuation
PID 值不准确
PID value is not accurate
进行出风温度自调
Make the air outlet temp adjusted automatically.
13.干燥室底端滴料
13. bottom of drying chamber is driping
1. 进风温度太低
2. 雾化空气压力太低
3. 压缩空气漏气
4. 进料量太大
1. air inlet temperature is too low
2. Atomizing air pressure is too low
3. Compressed air leak
4. Feeding capacity is too big
1. 增加进风温度
2. 打开设备后盖板将压力调至
2-3Bar(¢6 蓝色气管)
3. 检查各处连接是否漏气
4. 修改蠕动泵参数
1. increase air inlet temp
2. open back part of equipment and update the pressure to 2-3 Bar (¢6 blue air tube)
3. Check all the connection whether is leak
4. update peristaltic pump parameters
14. 通针不工作
14. Through need does not work
1. 空气阀门未开
2. 压力太小
3. 通针参数设定太大
4. 电磁阀损坏
1. Air valve is not open
2. Pressure too small
3. through needle setting value is too big
4. Solenoid valve damage
1. 打开阀门(¢4 白色气管)
2. 调大减压阀压力
3. 修改通针参数
4. 换电磁阀
1.Open air valve ( ¢4 white air tube)
2. Increase reducing valve pressure
3.update through needle setting value
4. Change solenoid valve
小型喷雾干燥机售后电话:021-61558629