沥青针入度仪英文资料;
An overview
The equipment is designed and manufactured in accordance with the technical requirements JTJ052-2000 1997. It applies to the determination of road asphalt, emulsified asphalt evaporation or distillation of liquid petroleum asphalt residue degree of penetration.
Automatic temperature control equipment is regularly automatically penetration characteristics; The device used for the test of time and temperature parameters.
The technical indicators
1, Temperature setting:Aircraft equipped with 25 ° C temperature parameters, users can arbitrarily set.
2, Time setting:5S aircraft equipped with time parameters, the user can arbitrarily set.
3, The scope of testing :0—70℃ Accuracy :0.1°C
4, The scope of time : 0-99S Accuracy :0.1S
5, The scope of needle accuracy : 0-50mm Accuracy:0.1mm
6, Needle penetration weight: 2.5g+0.05g
Acupuncture weight fixture : 47.5g+0.05g
The weight weight :50g+0.05g
Use
Face healthy permutations :
Set Temperature Control Time/temperature ▲▼ Results F1 Test
1, According to the “test” button that started a trial, the right window shows penetration, with the needle drop numerical increase, unit mm. Left window shows time reduced to 0.1 seconds flat.
According to the “test” button for the third Test, the left window shows that the “P”, the right window shows the penetration test, the mean value.
According to the “findings” key and the left window shows “1”, the right window shows the values of the first penetration test.
According to the “findings” key and the left window shows “-” right window shows the penetration values of the second test.
According to the “findings” key and the left window shows “3”, the right window shows the penetration values of the third test.
According to the “findings” key and the left window showed that the “P”, the right window of the third test showed the average degree of penetration.
Continuous according to the “results” button, and the average degree of penetration test, the cycle show.
If the new test to be done, we can directly “test” button to begin the new tests, it can be “/ temperature” button. results from the state, according to the “test” button and start a new trial.
2, According to the “temperature control” keys, manual control equipment is available for temperature control, temperature control lights, temperature control equipment. automatic temperature control in setting values, eliminate temperature control lights, temperature control equipment not, output natural cooling temperature of the state.
3, According to the “time / temperature” key, the left window shows the time or manual temperature control equipment, temperature lights, the left window shows the temperature. Time lights, the left window shows the time.
4, “set”, “▲”, “▼” key is used to set some internal parameters, users should not arbitrarily change these parameters. According to the “set” button, 2-3 seconds later, set lights every time “set” button, there is a new parameter.
Left window shows Right window shows
25.0 Setpoint SE(Said Setpoint )
5.0 Time TT
00.0 (Password ) LOC
(When passwords =123, continue to demonstrate the following parameters, it does not mean 123, set directly from the state)
00.0(Temperature correction value) CC (The same temperature and the actual temperature not found, through amendments to CC )
00.8(Temperature Control ratio ) P
-0.4(Temperature control static error ) EE(Finding is not the same temperature and the actual temperature setting, through amendments to EE )
010.(Output ) OUT
000(That displacement 0 points) CC0
000(That displacement 5.0points) CC1
000(That displacement 10.0points) CC2
000(That displacement 15.0points) CC3
000(That displacement 20.0points) CC4
000(That displacement 25.0points) CC5
000(That displacement 30.0points) CC6
000(That displacement 35.0points) CC7
000(That displacement 40.0points) CC8
000(That displacement 45.0points) CC9
000(That displacement 50.0points) CC10
According to the “F1” key is used in the displacement sensor calibration, according to the principle of “F1” key, the right window shows displacement. Meanwhile displacement scintillation.
Amended with 0.1 CC0 amended CC1 with 5.0 points, the same token ……..
Displacement sensor calibration parameters must CC0-CC10 all of the 11 established a “0” Then one calibration CC0 (0), CC1 (5) and CC10 (50). Amended with 0.1 CC0 amended CC1 with 5.0 points, the same token ……
5, “F1” key is used in the displacement sensor calibration, according to the principle of “F1” key, the right window shows displacement. Meanwhile displacement scintillation.
For example : Calibration CC0 according to the “F1” key to find the right window shows small displacement CC0 also emphasized the great value Instead regulation until the right window shows the value of small CC0 zero displacement.
Calibration CC1 according to the “F1” key to find the right window shows small displacement CC1 also emphasized the great value Instead CC1 small adjustment until the right window shows the value of displacement to 10.0.
Common Faults and Maintenance
A : First of all equipment switched on without inspection showed there were no power plugs tight contact sound.
B, Temperature control equipment : machines is not whether or not the line behind interpolation control, any temperature sensor placed in a water bath. temperature control whether the light is bright, if everything goes normal, and then checks the temperature set lower than the actual temperature.
C, The temperature : no thermometer calibration standards : The effects of temperature sensors and the mixture stirred into ice water, adjusting the temperature that values make that value plus the show will be equal to the standard value. (Revised negative values)
D, No displacement : whether the inserted lines inspected, according to the “F1” key. the right side window to see whether there are indications that the promotion guide rod displacement sensor data will change accordingly.
E,Needling: needle into the inspection line, it plugs inserted, it can set bright light, bright as can be by the defense.